| Hand tool 6-32 | Insulated electric tools. Can be used on equipment with voltage up to 1000V. | DSTU GOST 11516:2014 |
| Electric soldering iron 40VT | U=220V;P=40Vt;50/60Hz | GOST 7219-83; |
| Automatic switch 3F 100 A (small size) | İn-100A | GOST P 50030-3-2012.(MEK 600947-3:2008) |
| Un- ~230V/400,50hz | ||
| Breaking current – 25 k A | ||
| Automatic switch 16 A (1 phase) | İn-16A | IEC/EN 60898-1: 2020 |
| Un- ~230V/400V,50hz; Breaking current – 15 k A | IEC/EN 60947-2:2016 | |
| Electric switch 1 pole | 220V/240V;10A | GOST 51324.1-2012:MEK 60669-1:2007; |
| Electric switch 1 pole (hermetic) | 220V/240V;10A | GOST 51324.1-2012:MEK 60669-1:2007; |
| Luminescence lamp LB 18 (or analog) | GOST IEC 60598-2017 | |
| SOKOL G13-tubular; With operating throttle | GOST IEC 62776-2019 | |
| T8 0.6m; P = 12-18Vt; U = 85-265V; 2FT; Color: white; IP20; 1100- 1350LM.SMD2835 | ||
| Luminescence lamp LB 36 (or analog) | Sokol G13-tubular; With operating throttle; | GOST IEC 60598-2017 |
| With operating throttle | GOST IEC 62776-2019 | |
| T8 0,6m;P=12-18Vt;U=85-265V;2FT; Color: white;IP20;1100- 1350LM.SMD2835. | ||
| Cable thimble TM 70-12-13 | Copper coated Dimensions:M12;D=13mm;B=40mm;L=105mm;d=27mm;d1=21mm; Material: electrical copper M2;U=2000V | GOST 7386-80;. |
| Distribution board 250A With converter-separator 60x70 | Converter-separator 250A;400V;Output Automat:3F 100A-2 ea.;3F 32A-2 ea. | GOST 14254-2015 |
| Cable scissors | 25-400mm hydraulic | GOST 12.2.118-2006 |
| Cable KQ 2 x 4 mm2 | Up to 0,66/1kV. Copper; D=2x4mm.Insulation: Non-flammable rubber, resistant to abrasive agents and soft bending | GOST 31996-2012;GOST 22483-2012;GOST 31565-2012 |
| or analog | ||
| Cable KQ 3 x 16-1 x 10mm2 | Up to 0,66/1kV. Copper Insulation: Non-flammable rubber, resistant to abrasive agents and soft bending | GOST 31996-2012;GOST 22483-2012;GOST 31565-2012 |
| or analog | ||
| Cable KQ 3x35x1x16 mm2 | Up to 0,66/1kV. Copper Insulation: Non-flammable rubber, resistant to abrasive agents and soft bending | GOST 31996-2012;GOST 22483-2012;GOST 31565-2012 |
| or analog | ||
| Cable KQ 3x50x1x25 mm2 | Up to 0,66/1kV. Copper Insulation: Non-flammable rubber, resistant to abrasive agents and soft bending. | GOST 31996-2012;GOST 22483-2012;GOST 31565-2012 |
| or analog | ||
| Cable KQ 3x6x1x4 mm2 | Up to 0,66/1kV. Copper Insulation: Non-flammable rubber, resistant to abrasive agents and soft bending. | GOST 31996-2012;GOST 22483-2012;GOST 31565-2012 |
| or analog | ||
| Cable KQ 3x70-1x25 mm² | Up to 0,66/1kV. Copper Insulation: Non-flammable rubber, resistant to abrasive agents and soft bending | GOST 31996-2012;GOST 22483-2012;GOST 31565-2012 |
| or analog | ||
| Grounding cable: 1x70mm2 | Up to 0,66/1kV. Copper | GOST 31996-2012;GOST 22483-2012;GOST 31565-2012 |
| Grounding cable: 1x50mm2 | Up to 0,66/1kV. Copper | GOST 31996-2012;GOST 22483-2012;GOST 31565-2012 |
| Grounding cable: 1x16mm2 | Up to 0,66/1kV. Copper | GOST 31996-2012;GOST 22483-2012;GOST 31565-2012 |
| Wire PPV 2x4 mm2 | Copper; Diameter D=4mm2;U=400V;İ=120A;50Hz. | GOST 6323-79 (ST SEV 587-87); |
| or analog | Insulation:PVX. | |
| Welding cable 1X50 mm2 | U=1000V İ=250A | GOST 31996-2012;GOST 22483-2012;GOST 31565-2012 |
| Resistant to combustion and abrasive substances; Soft with high bending. | ||
| Heat-resistant self-adhesion electrical tape KF 0.5 mm2 | Heat-resistant Electric insulation material, self-adhesive, siloxane polymer material | GOST P 57032-2016 |
| Cardboard cutting scissors | GOST P 51268-99 | |
| UPS 1000 VA | 220V/220V | GOST IEC 62040-3-2018 GOST MEK 62040-1-2-2009 |
| UPS 2000 VA ART | GOST MEK 62040-1-2-2009; GOST IEC 62040-3-2018 | |
| 2000VA; 1200Vt; 220/220VAC | ||
| Relay RRT 32 | 28V; 37A: Automatic regulating voltage relay; Limit: 27V-29V, I = 4A, Protection operating current: 5-6A, | GOST 17523-85;. |
| Drill perforator | Elektric drill perferator: | EN 61000-3-2-2021, EN 60745-1-2011 |
| 0,9-1KVt; 230V | ||
| Electric switch n2 (bipolar) (inside the wall) | 220V/240V; 10A | GOST 51324.1-2012:MEK 60669-1:2007; |
| A set of electric tools | Insulation handles: pliers, screwdrivers, wrenches, barbell, meter, soldering iron, cutting tool, indicator, flashlight, tester | DSTU GOST 11516:2014 |
| Elektriс drill | Electric drill 230V pulse, 850Vt, 3000 d / d, 51000 pulse / min, 2-speed, Max.diameter 13mm, Min.1,5mm, Max. Torque | GOST IEC 60745-2-6-2014 |
| Electric shield PR-11 | U = 380-660V; 50 / 60Hz; Input Output machines: 3F: 160A-2pcs; 100A-2pcs; 63A-2pcs; 40A-4pcs; 1F: 25A-4pcs; 16A-2pcs; Zero tire; Grounding device; Tires Copper, Door handle dielectric and locked. Voltmeter and Ammeter. With Legs L = 20cm. | GOST 14254 |
| IP54; Protection class:GOST 14255-96; automate (schneider,ABB,Siemens)630A; | ||
| Power strip (with drum) 50 M | Copper multicore 2 * 6mm, 220-240V, 400V Insulation | GOST 31223-2012 |
| Electric jigsaw | 800 Vt; 220V; 50Hz; | GOST IEC 62841-2-11-2017 |
| Frequency:0-2500 d/d | ||
| Projector 400W LED | 220 V, 50 Hz, 6000K (daylight) (safe zone) | GOST 14254-2015 IP65; GOST IEC 62722-2-1-2017 |
| Electric socket E27 | GOST IEC 60238-2012: | |
| U=250V;İ=6A; ceramic | ||
| Electric plug | GOST IEC 60309-1:2016; İP20 | |
| U=250V ; İ=16A; | ||
| Socket (wall nm mounted) | socket, wall mounted; U = 250V; I = 16A; Grounding device | GOST IEC 60309-1-2016 |
| Magnetic starter 250A with relay | Uk = 380V; Heat relay: 20-300A. | GOST 2491-82; |
| Cable thimble TM 50-10-11 | Copper coated Dimensions: M10; D = 11mm; B = 40mm; L = 105mm; d = 27mm; d1 = 21mm; Material: Electrical Copper M2; U = 35kV. | GOST 7386-80; |
| Regulator 3 phase 10kva | Gərginlik tənzimləyicisi 10kVA;3F;Giriş gər:250-450V;Output -380V | IEC 60076-24:2020 |
| Lagonda small 125 mm | ДСТУ EN 60745-1:2014 | |
| 900Vt;11000d/d;Diameter -round-125mm;2.2lq. | ||
| Cable KQ 12x2,5 mm2 | Copper U=0,4kV; İ=28A; Insulation: rubber, soft bending | GOST 31996-2012;GOST 22483-2012;GOST 31565-2012 |
| Magnetic starter 380V 160A | Uk=380V; İ=160A; Heat relay:20-200A | GOST 2491-82;. |
| Cable thimble press | EN ISO 4413 | |
| 16-400 mm2 (hydraulic) | ||
| Led spot 300x300 mm | 25Vt 85-265 V | EN 60598-1:2020 |
| Dimensions:300x300;P=25Vt;U=85-265V: IP40; 6500K; 350-450Lm | ||
| Led spot 600x600 mm | 48Vt 100-240 V | EN 60598-1:2020 |
| Dimensions:600x600;P=48Vt;U=100-240V:6500K.450-550Lm. | ||
| Projector explosion-proof 400W led | EN 60598-1:2020: GOST 30852.13-2002 | |
| 220 V, P=400Vt; 6500K | ||
| Cable thimble 400 mm2 (Copper) | GOST 7386-80 | |
| Material: electrotechnical Copper M2; 1000A; 1000V | ||
| Connecting Copper pipe (Ø50mm ) | Pipe; Material: electrotechnical Copper M2;350A;1000V | GOST 21091-82; |
| Connecting Copper pipe (Ø70mm ) | Pipe; Material: electrotechnical Copper M2;350A;1000V | GOST 21091-82; |
| Connecting Copper pipe (Ø95mm ) | Pipe; Material: electrotechnical Copper M2;350A;1000V | GOST 21091-82 |
| Drill perforator (large) | Electric drill perforator: | 2006/ 95/EC, EN 55014-1, EN55014-2, EN 61000-3-2, EN 60745 |
| 230 V, 1500Vt; 3600 pulse minute, 770d/d, | ||
| Drill (with battery) | Electric drill battery: Battery voltage: 18-20V; Battery capacity | 2006/ 95/EC, EN 55014-1, EN55014-2, EN 61000-3-2, EN 60745 |
| 1.5 A / S; Max. Torque: 42 Nm; spindle speed: 400 / 1300d / d; | ||
| Maqnit işəsalıcı LC1D09M7C or analog | TeSys D IEC contactor, 9 A, 3 P, 5 HP at 480 VAC, 220 VAC 50/60 Hz | GOST 2491-82: |
| Magnetic starter LC1D25M7C or analog | GOST 2491-82: | |
| U=250V;İ=6A | ||
| Electromagnetic relay that drives the reducer | GOST P 17523-85 | |
| 24V, 40A, | ||
| Terminal MOS | GOST P 52230-2004 | |
| 24Vdc/24VdcACT | ||
| Capacitor- E62.C58 471E40 or analog | E62.C58 471E40. 47nf, 1700v MKP | GOST P 57440-2017 |
| Condensator PE, 0.47µF, 2800DC, 1700AC, 30x58, oil filled, protection installed: | ||
| Thermo relay LRD16C or analog | GOST 27895-88 | |
| U=250L;İ=16A; | ||
| Magnetic starter 10A (Uc 24V AC/DC) Relay ilə | 3F Uk=24V; İ=10A; 3F:Relay:2-15A | GOST 2491-82 |
| ABB CA4-22M or analog | 1SBN010140R1122 | GOST 2191-82; |
| ABB BEA16-4 or analog | 1SBN081306T1000 | GOST 2191-82. |
| ABB MS132-16 or analog | 1SAM350005R1011 | GOST 2191-82 |
| 10-16A | ||
| ABB MS132-6.3 or analog | 1SAM350005R1009 | GOST 2191-82; |
| 4-6 A | ||
| Auto switch ABB AF16-30-10 /1SBL177001R1310/ | GOST 2191-82 | |
| 7.5kVt 250VAC | ||
| Phase relay - DPB01 | GOST 3699-82 | |
| P/N:18150102150 or analog ; | CM48 220V; | |
| Phase relay - K8AB PH or analog | 6A; 250V, Output voltage control relay; Control range: 200-500V AC | GOST 3699-82 |
| Phase relay - K8AB PH1 or analog | Voltage Control Relay; Dimensions: 22.5x90x100mm; Control range: 200-500V AC; Operating temperature: -10 + 60C | GOST 3699-82 |
| Contactor 160A 380V | GOST 11206-77 | |
| Un=400V;İ=160A;Uk=380V | ||
| Megohmmeter M4100/3 (ЭС0202/2-Г) or analog | 0-1000KOm,0-200Mom 1000V analog. | GOST 8.401 |
| Generator panel power supply 4NIC -K120 (220V / 24V 5A) | Power supply: 4NIC-K120; U = 220V / 24VDC; İ = 5A | GOST 2291-77. |
| Transformer 3 phase.100VA 600VAC / 19VAC | Ug=600VAC;Uç+19VAC;P=100VA. | GOST 19294-84; |
| Fuse - 30. A,1000VDC/100KAIC | Fuse :İ=30A;U=1000V; | GOST IEC 60238-2012 |
| Fuse - 6A, 750VAC,1000VDC,100KAIC | Fuse :U=750V;İ=6A; | GOST IEC 60238-2012 |
| Fuse 200A -170M4700 | Fuse :İ=200AU=630V | GOST IEC 60238-2012 |
| Magnetic starter 63A (Uc 220V AC) Relay ilə 3F | Uk=220V AC; 63A; Relay:10-65A. | GOST 2491-82: |
| Magnetic starter 80A (Uc 220V AC) Relay ilə 3F | Uk=220V AC; 80A; Relay: 20-85A | GOST 2491-82:. |
| Fuse - KTK-2 600VAC 8A or analog | Fuse :U=600V AC ;600V AC ; İ=8A | GOST IEC 60269-1-2016 |
| Fuse - KTK-2 600VAC 2A or analog | Fuse ; U=600VAC; İ=2A | GOST IEC 60269-1-2016 |
| Fuse - KTK-6 600VAC 6A or analog | Fuse ; U=600V AC; İ=6A | GOST IEC 60269-1-2016 |
| Fuse - KTK-10 600VAC 10A or analog | Fuse ; U=600V AC; İ=10A | GOST IEC 60269-1-2016 |
| Fuse - KTK-4 600VAC 4A or analog | Fuse ; U=600V AC; İ=4A | GOST IEC 60269-1-2016 |
| Resistance-RX-20, | 100VT, 250M | GOST IEC 60238-2012 |
| or analog | Resistor wire adjustable processing 100W 100LR; | |
| Converter switch ZB2BJ2C | GOST 16708-84: | |
| 230V AC | ||
| Refrigerating fan motor 24V Ie24 / 02 1334 | GOST 33660-2015 | |
| 24V 300d/d | ||
| Led lamp E40 220V 400Vt | 220-240VAC, 200Vt, E40, 6500K, LED type, 20000Lm, 50000saat, 80*80*132mm | GOST IEC62612-2019, |
| Heating tires for YZ08 800kW DC motors | U=220V; İ=1A. | GOST IEC 60079-30-2-2011 |
| Oscilloscope - Rigol MSO1104Z | 4-channel oscilloscope with 100MHz bandwidth: Memory-12Mbytes; With built-in 16-channel logic analyzer. JK display: 17.8cm (800x840pixels) | IEC 60068-2-27 (2008) |
| Lot 2 : Control blocks | ||
| Control panel - Air Control B | 18-24V AC, AI 4-20mA,DI 12-24V | GOST 10393-2014: |
| Control panel - Air Control 3 | 18-24V AC, AI 4-20mA,DI 12-24V | GOST 10393-2014: |
| Control panel - Air Control P | 18-24V AC, AI 4-20mA,DI 12-24V | GOST 10393-2014: |
| AIRLOGIC2 Quincy el. Compressor control unit (45kW) | LR244507; Type 4;Art.№PPBE0713;U=24VAC/16VA,50/60Hz;K01-K03:RC Protection;U=250VAC/İ=10A Max | GOST 10393-2014:. |
| Control unit - InteliDrive Lite ComAp | Engine controllers: Automatic and manual; programmable; Electronic block EBU-J1939; analog measurement output (VDO, datcon, etc.); Configurable: USB, RS485 / RS232 / modem / communication module; 7-dual output; 7- dual input; 9 analog inputs: 3-resistive, 4-voltage, 2-non-configurable; | IEC 60068-2-27 (2008) |
| Control unit - InteliGenNT ComAp Controller | For generator: Modbus J1939; 6 dual inputs and 6 dual outputs; RS485 universal communication port; RS232 communication port; CAN1, CAN2. | IEC 60068-2-27 (2008) |
| Synchronous block- WOODWARD SPM D11 Part no 8440-1706 D | GOST IEC 60255-5-2014 | |
| 12-24VDC, 10Vt | ||
| Lot 3 : Electronic parts for CAT 3512 diesel generator | ||
| Diode bridge (M50100THC1600-8700) or analog | GOST 30617-98 | |
| Vf 1.2V, Vr 1600V, 100A | ||
| Diode bridge (M50100THC1600-8701) or analog | GOST 30617-98 | |
| Vf 1.2V, Vr 1600V, 100A | ||
| Heater for CAT 3512B, with thermostat | GOST 13268-88 | |
| 230V , 2-4A | ||
| The power supply unit of CAT3512 is 4NIC-CD240 or analog | 220V AC/24VDC 10A | İP65, |
| GOST IЕС 61558-2-5-2013 | ||
| Varistor (CK260 4P6009 1206) | Umax reverse=400V;İmax reverse=5A;U=820V 40KA;İmax=250A | GOST IEC 61051-2-2013 |
| CAT3512B diesel generator. | ||
| CAT 3512 generator exit stator winding | U=600V; 50Hz; | GOST IEC 61000-4-3-2016, |
| IEC 63245-1 | ||
| Lot 4 : Special Cable sets | ||
| TDQ (225DBZ)Cable-TD*PWR-E313-200-04-25-B(SL-PL313-200) | Cable (Copper) 1x328mm; L = 26m; U = 2000V; I = 1250A; F = 50 / 60Hz; Insulation type: PenaPolistrol and other technically mixed non-combustible material | İEEE 1580; |
| TDQ (225DBZ)Cable-TD*AUX-E014-20-200-04-25-B(SL-AL025-200) | Cable (Copper) 20x2,5mm; L = 61m; U = 600V; I = 80A; F = 50 / 60Hz; Insulation type: PenaPolystrol and other technically mixed non-combustible material; | İEEE 1580 |
| TDQ (225DBZ)Cable-TD*CTL-E016-42-200-04-25-B(SL-CL015-200) | Cable (Copper) 42x1,0mm; L = 61m; U = 600V; İ = 80A; F = 50 / 60Hz; Insulation type: PenaPolystrol and other technically mixed non-combustible material | İEEE 1580; |
| Cable - AUXILIARY POWER LOOP, COMPLETE, L=80 M p\n BA4061107 or analog | Power cable from Top Drive's VFD room to the derrick: Copper; L = 80 M p \ n BA4061107: 3X646 MCM | GOST Р МЭК 60719-99 |
| GOST IEC 61316-2017 | ||
| Cable - MAIN POWER LOOP, COMPLETE p\n BA4061106 or analog | Power cable from derrick to the Top drive engine: p \ n BA4061106: 3X646MCM | GOST Р МЭК 60719-99 |
| GOST IEC 61316-2017 | ||
| Cable – for operator panel p\n 4061112 or analog | Signal cable from Top Drive's VFD room to the control panel: Copper: 7x1,5mm2; 30181809-9; | GOST Р МЭК 60719-99 |
| GOST IEC 61316-2017 | ||
| Cable – for operator panel p\n 4061113 | Signal cable from Top Drive's VFD room to the control panel: Copper: 7x1,5mm2; 30181884-9 | GOST Р МЭК 60719-99 |
| GOST IEC 61316-2017 | ||
| Lot 5 : Solenoid valve, relay, encoder and sensors | ||
| Relay - DRM570024 LT 7760056097 or analog | 7760056104, 230VAC, 4CO, Dimensions:21.5x28x36mm | GOST 17523-85 |
| Drawworks and rotary oil sensor--SA1111E-S5-K2 or analog | Oil pressure Relay :SA1111E-S5-K2; Body protection standard; NEMA с 1 по 4X и 13; | EN 60079-0:2009; |
| Explosion protection: NEMA 7; Class 1, group: BC, D; NEMA 9, class 2, group: E, F, G; Converter type: SPDT or DPDT; Pressure limit 1200F 12-inch (82.6bar); Stainless steel; Resistant to chemicals, petroleum products & other abrasive agents | EN 60079-1:2007 | |
| IP65 | ||
| Encoder F3688 Kuebler rope distance measuring device | Sendix F3688; Size: D = 36mm; 16 bit-single-circuit; 16-bit-multi-circuit; Hollow shaft Max: 10mm; Size = 36x42mm; U = 10… 30V DC; Temp: -400C + 850C; IP65; Rotation speed Max = 10000 min-1; Shaft = 6 / 8mm | IP65. |
| EN 60529-1991 | ||
| Circuit breaker delay unit MT-MN 033682 or analog | 220-250V | GOST IEC 60255-1-2014 |
| Control winding MN 033671 or analog | 200-250V | GOST IEC 60255-1-2014 |
| Encoder 8.A02H.525A.1024.0030-EX or analog | IP65. | |
| 5-30 VDC, | EN 60529-1991 | |
| Relay IG-AVRi or analog | Input voltage:18V AC;Output±10V;İ=Max20mA;Power:5VA | GOST IEC 60309-2:416; |
| Electric sensor WBK1V1DUO1-I or analog | Gauge transformer: WBK1V1DUO1-I AC 210 Vt 24 V. | GOST P 56750-2015 |
| RPD panel resistor- L7 BV 09549 or analog | ZWS 30/145 18R 10% 3 | GOST 28608-90 |
| resistor:L7; BV 09549ZWS 30/145 18R 10%; | ||
| Temperature Relay KSD-33F/1H or analog | U=250V;İ=6A; | GOST IEC 60238-2012 |
| Residual current device | 4P 40A 30mA. | GOST 17242-86 |
| Temperature and humidity transmitter 6ACC10DB p/c 1400003792 or analog | ||
| 24VDC | ||
| ABB PLC Encoder module - RTAC-01 6410038040949 or analog | GOST 29125-91 | |
| Solenoid valve (PVEH) 11084101; 02ATEX459X or analog | 24V, 0.5A, 8Vt | İP67 EN 60529-1991 |
| Air pressure transmitter 82234 2088G4 S22 A1D484K6Q4: SERIES No9472788 or analog | OUT PUT HART 4-20Ma; MaxWp.4000PS/27.6mPA Cuppy 10.5-36VDC; CALOTO 275 BAR | İP67, EN 60529-1991 |
| ADJUSTABLE PRESSURE SWİCH MODEL:232P43C6HN or analog | ;RANGE:1000T0 3100 PİSG:PROFF PRESSURE:9750 PSİG;MAXİMUM SYSTEM 6500PSİG | İP67 EN 60529-1991 |
| Aerospase Controls MODEL:122P82C6N540 or analog | RANGE:3TO30PSİG;ELEC 11AMP1/4HP@125/250VAC5,0AMP RES,@28VDC | İP67 EN 60529-1991 |
| Oil pressure gauge: AROFLEX EPDB6-315SD or analog | TYP:EEX EM1.1-C-T4):Nr:M38 VDC24V;2A;52W | İP67 EN 60529-1991 |
| Inductive sensor-NCB10-30GM40-N0-15M part.no 106283 or analog | NCB10-30GM40-N0-15M part.no 106283 | İP67 EN 60529-1991 |
| RELAY 24VDC 4AOBOC 10 A | GOST 17523-85 | |
| İ=10A;U=24V DC;4AOBOC | ||
| Relay -24VAC/DC 8NO/1NC PSR-SC | GOST 17523-85 | |
| Umax revers=24V; İmax revers=5A ; | ||
| Resistor 3.32Kohm | 3.32Kohm, 1/2W, 1% U=250V; İ=6A | GOST IEC 60238-2012 |
| Signal converter - NewPwr NPEXA-C311P or analog | Signal converter | IEC 61326-3-1-2015 |
| Output 1: İn=4-20mA; | ||
| Output 2: İn=4-20mA | ||
| Input: 18-32V DC | ||
| Temp. Signal converter - NPWD-CD55D;0-10V;24VDC; or analog | Umax revers=400V;İmax revers=5E;U=820V 40KA;İmax=370A; | GOST 21342.9-2016 |
| TOP11B 11sa) (8SA, 11SA) üçün | ||
| Temperature sensor - PT100;WZP-021N or analog | Umax reverse=400V;İmax reverse=5E;U=820V 40KA;İmax=370A; | GOST 21642.9-2016. |
| For TOP11B 11sa) (8SA, 11SA). | ||
| ABB S53 Relay or analog | U=250V; İ=6A; | GOST IEC 60238-2012 |
| EM-DR1-IS-5-RTB-28 v/v P/N 60004-003 or analog | Galvanic unopened barrier: Input voltage: 12-24V DC; U; | GOST 21842.9-2016 |
| (No GOST found) | ||
| Lot 6 : Touch control panels | ||
| SCR control panel- MP377 15" Touch (6AV6 644-0AB01-2AX0) or analog | 24V, 1.8A, TFT, 1024*768, | IP 65, EN 60529 - GOST 14254-96 - МЭК 529-89 – IEC 60529 |
| Windows CE, 1 x RS422, 1 x RS485, 2 x Ethernet (RJ45) | ||
| Monitor.2402969 BL PPC153000HH CN BLPP3000 or analog | CNBLPP3000; İ=1,9A; U=24V DC | GOST PB 29.005.0171 |
| SCR control panel - MP277 10" Touch (6AV6 643-0CD01-1AX1) or analog | Touch screen monitor; 10 inches; 800x600 pixels; 65536 colors; 24V DC; INTERFACE: 1xRS422 / RS485 MPI / Profibus DP; 2x10 / 100Mbit / S RJ45, with SD / MultiMedia memory card, 2xUSB 2.0. | IP 65, EN 60529 - GOST 14254-96 - МЭК 529-89 – IEC 60529 |
| Panel - TP1500 Comfort 6AV2 124-0QC02-0AX0 or analog | Comfort 6AV2124-0QC02-0AX0; Configuration memory -24Mb.V11 SP2;15dyüm | GOST PB 29.005.0171 |
| SCR control panel -SİEMENS MP377 15" Touch (6AV6 644-0AA01-2AX0) or analog | 24 VDC, 1.5A, 36 W, 15 ", 6AV6 644-0AB01-2AX0, touch screen, 1 x RS422, 1 x RS485, 2 x Ethernet (RJ45) | IP 65, EN 60529 - GOST 14254-96 - МЭК 529-89 – IEC 60529 |
| HMI Panel PC, 15” Touch Screen or analog | 100-240 VAC, 0.5-1 A, p\n 27611, id-10000024194, 15", touch screen | IP 65, EN 60529 - GOST 14254-96 - МЭК 529-89 – IEC 60529 |
| Lot 7 : Modules, adapters, motherboards and power supplies of various inverter-PLC systems | ||
| ABB PLC profibus adapter RPBA-01 3AUA0000000914 or analog | GOST 29125-91: | |
| ABB PLC control module - RDCU-12C 3AUA0000036521 or analog | GOST 29125-91 | |
| ABB PLC optical distributor - APBU-44C APBU-44CE 6468 8391 c or analog | GOST 29125-91 | |
| Contactor ABB A300-30 (or analog) | 3F;İ=300A AC;U=690AC/220DC;Tip:3HO;Uk=230VGOST | IEC 60238-112 |
| Contactor ABB AF370-30 (or analog) | 1SFL607002R1311;U=1000V; 50/60Hz;600V AC-520A; | IEC 60238-112 |
| ABB NBRA-666 P/id 59012134 Breaking Chopper (with resistance) or analog | P/n 59012134 | İD KOD:59012134 |
| Brake system | ||
| Soft starter block - Altistart 22 88A ATS22D88Q | ATS22; İ=88A; 3F; Engine:45kVt-400V. | IEC 60068-2-27(2008) |
| Soft starter block - Altistart 22 100A ATS22C11Q | İ=100A;3F;Engine:55kVt-400V.Altistart 22 100A | IEC 60068-2-27(2008) |
| Soft starter block - Altistart 22 162A ATS22C17Q | İ=162A;3F;Engine:75kVt-400V.Altistart 22 162A | IEC 60068-2-27(2008) |
| Consistometer main card P/N 20-101-0456 or analog | GOST 29125-91: | |
| P/N 20-101-0456 | ||
| Inverter/18.5KW | 690V 22A IP21; F=50/60HZ | GOST 24376-91: |
| Voltage switch 500Vt 63V 3156098 | P=500Vt; U=63V: | IEC 60063 |
| PROFIBUS DP/V1 12 MBd FIELDBUS COUPLER-P/N 750-333 or analog | Module system profibus (signal transmitter): | IEC 61326-3-1-2015 |
| 24V DC;10A;EEx nA II T4;İP20;RS 485; | ||
| For SBC Controller Kit w/Profibus | EN 50170 | |
| TOP11B 11sa) (8SA, 11SA) | ISO 7498 | |
| IEC 1158-2 | ||
| For Platу Elmago brake system (ZJ50D rig) | EN 61086-2:2005 | |
| Plate 6SE7090-OXX84-3DB1 Siemens | EN 61086-2:2005 | |
| Controller 6ES7322-1BL00-0AA0 Siemens | Programmable controller:S7-300;SM 322;Discrete signal Output lı:32 Output :24VDc/0,5A;Cəm:8A; | GOST P MEK 61131-1-2016;61131-6-2015 |
| Block 6ES7 212-1AB23-0XB8 | SIMATIC S7-200 CN;CPU222; DC power supply: 8 Di DC; / DO DC 4 KB software / 2 KB supplied; | GOST P MEK 61131-1-2016;61131-6-2015 |
| Power supply block - SITOP PSU100S 6EP1334-2BA20 DC 24V/10A | Adjustable power supply; Input: AC 120 / 230-500V; Output: DC 24V / 10A; 240Vt; 50 / 60Hz | GOST IEC 61204-7-2014; |
| Block S 6ES7321-1BL00-0AA0 | GOST P MEK 61131-1-2016;61131-6-2015 | |
| 24V, 15mA, 32 Output lı | ||
| Power supply block SIMATIC6ES7 307-1BA01-0AA0 | IEC / EN 60898-1, GOST IEC 60947-5-2-2012 | |
| 400/230V Power supply block 24V; | ||
| PLC module - SIMATIC S7-300 CPU 315-2 PN/DP 6ES7315-2EH14-0AB0 | GOST P MEK 61131-1-2016;61131-6-2015 | |
| 24V, 750mA, | ||
| 800 kVt DC air filter (FKK 1/1 Е5/592Х592Х290) | ZJ rigs, for 800kVt DC engines: (FKK 1/1 Е5/592Х592Х290) | GOST P EN 779-2014 |
| Block S7200 CPU 6ES7212-1AB23-0XB0 | U=28V;8 discrete Input=24V;6 discrete | GOST P MEK 61131-1-2016;61131-6-2015 |
| Output =24V/0,75A;program memory:4Kb;free port:1 PPİ /MPİ;2 Expansion module | ||
| 24V DC power supply panel 309MX | Power supply block:220VAC/24V DC | GOST 2291-82; |
| SCR conditioning motor YDK3000-4 3Kvt 3 phase 50hz | Electric motor;YDK3000-4;P=3Kvt;3F; 50Hz;U=380V;1500-3000d/d. | GOST 2391-82; |
| Brake block-6SE7031-6EB87-2DA1-Z or analog | U=250V; İ=16A; | GOST P MEK 61131-1-2016;61131-6-2015 |
| PLC module - 323-1BLOP-0AA0 or analog | GOST P MEK 61131-1-2016;61131-6-2015 | |
| Dİ16. DO16 XDC 24V | ||
| PLC module - 6ES7350-1AH03-0AE0 or analog | GOST P MEK 61131-1-2016;61131-6-2015 | |
| RS422, 24V, 160mA, 4.5Vt | ||
| PLC module S7-200CN or analog | PLC processor | GOST P MEK 61131-1-2016;61131-6-2015 |
| memory 10kByte, 24V, | ||
| Relay socket - PLC-BSC-24DC/21-21 | GOST 17523-85 | |
| 24V , 14*80*94mm | ||
| Power supply block - SITOP PSU300B 6EP1436-2BA10 or analog | 400-230VAC/DC24V 20A | IEC / EN 60898-1, GOST IEC 60947-5-2-2012 |
| PLC Adapter-6ES7972-0CB20-0XA0 PPI/MPI/DP | Network adapter: USB-MPI and Cable: USB v MPİ/DP/PPİ-S7-200/300/400 PLC: | GOST P MEK 61131-1-2016;61131-6-2015 |
| PLC converter-RS485/RS422/232 TIA/EIA FTDI or analog | Signal converter module: RS485/RS422/232 TIA/EIA FTDI; magnetic insulation; | GOST P MEK 61131-1-2016;61131-6-2015 |
| ABB software - Drive Composer PRO DCPT-01 (licensed) or analog | Ean:0696505453795: DCPT-01;UPC | EN/IEC 60068-2-27-1995 |
| 696505453795: Licensed software. | ||
| PROFIBUS DP 6ES7972-OBB12-0XA0 or analog | GOST P MEK 61131-1-2016;61131-6-2015 | |
| U=250V; İ=6A; | ||
| Driller speed pedal | IEC-61508, DIN V 19250/ DIN V VDE 0801, EN 954-1 | |
| U=250V; İ=6A; | ||
| ABB PLC profibus adapter FPBA-01 or analog | 6.43818E+12 | IEC-61508, DIN V 19250/ DIN V VDE 0801, EN 954-1 |
| ABB PLC Encoder module - FEN-31 or analog | 68978955 (68978840) | IEC-61508, DIN V 19250/ DIN V VDE 0801, EN 954-1 |
| ABB system card or analog | IEC-61508, DIN V 19250/ DIN V VDE 0801, EN 954-1 | |
| ACS 880-MU-ZCU-12 ZMU-02 (AINF2_V2.40.3.0) 24VDC | ||
| ABB İNV.PLATA 69037615 E 1/4 BGDR-01C or analog | IEC-61508, DIN V 19250/ DIN V VDE 0801, EN 954-1 | |
| 3AUA0000074145 | ||
| ABB PLC control module or analog - | BCU-02 3AUA0000110429 | GOST P MEK 61131-1-2016;61131-6-2015 |
| PLS USB-COM RS232/485/MPI Cable or analog | 5 VDC, 260mA, 921600 bit/s | GOST P MEK 61131-1-2016;61131-6-2015; GOST Р 55024-2012, |
| Windows 10 driver | GOST Р 55032-2012 | |