Schneider Breaker tripping device Micrologic 6.0E
NQ
range
Masterpact
range of product
Masterpact NW
product or component type
Control unit
trip unit name
Micrologic 6.0 E
trip unit technology
Electronic
range compatibility
Masterpact NW08...40
Masterpact NW40b...63
Masterpact NW H10
Masterpact NW H2 corrosion protection
device application
Distribution
Number of poles
3P
4P
protected poles description
4t
3t
3t + N/2
trip unit protection functions
Selective + earth-fault protection
protection type
For overload protection (long time)
for short time short-circuit protection
for instantaneous short-circuit protection
for earth fault
Trip unit rating
800 A at 50 °C
1000 A at 50 °C
1250 A at 50 °C
1600 A at 50 °C
2000 A at 50 °C
2500 A at 50 °C
3200 A at 50 °C
4000 A at 50 °C
5000 A at 50 °C
6300 A at 50 °C
network type
AC
network frequency
50/60 Hz
Circuit breaker mounting mode
Drawout
Complementary
Long-time pick-up adjustment type Ir (thermal protection)
Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range
0.4...1 x In
Long-time protection delay adjustment type tr
Adjustable 9 settings
[tr] long-time protection delay adjustment range
0.7…16.6 s at 7.2 x Ir
0.7…24 s at 6 x Ir
12.5…600 s at 1.5 x Ir
thermal memory
20 mn
Short-time protection pick-up adjustment type Isd
Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range
1.5...10 x Ir
Short-time protection delay adjustment type tsd
Adjustable
[tsd] Short-time protection delay adjustment range
0…0.4 s I²t=off
0.1…0.4 s I²t=on
Instantaneous protection pick-up adjustment type Ii
Adjustable 9 settings
[Ii] instantaneous protection pick-up adjustment range
2...15 x In
Off
Ground-fault protection pick-up adjustment type Ig
Adjustable 9 settings
[Ig] ground-fault protection pick-up adjustment range
0.2...1 x In for 400 A < In < 1250 A
0.3...1 x In for In <= 400 A
500...1200 A for In >= 1250 A
Ground-fault protection time delay adjustment type tg
Adjustable
[tg] ground-fault protection time delay adjustment range
0…0.4 s I²t=off
0.1…0.4 s I²t=on
earth-leakage protection
Without
zone selective interlocking ZSI
With
local signalling
3 LEDs (red) for electrical fault
1 LED (red) for internal error
display type
Digital display
type of measurement
Energy meter
communication of data
Measurement readout
Protection and alarm settings
Environment
ambient air temperature for operation
-25…70 °C
ambient air temperature for storage
-40…85 °C