DWCT
size
| Dimensional Drawing |
|
| Width | 60 mm |
| Altitude | 178 mm |
| Degree Of Depth | 49.3 mm |
| Spacing Of Wells | 168 mm |
ambient condition
| Ambient Temperature (Operation) | -25 °C ... 60 °C |
| Ambient Temperature (Storage / Transport) | -25 °C ... 85 °C |
| Almissible Humidity (Storage / Transport) | 95% |
| Air Pressure (Operation) | 80 kPa... 106 kPa (* height up to 2000 m above sea level) |
| Air Pressure (Storage / Transport) | 70 kPa... 106 kPa (* High up to 3000 m) |
| Protection Level | IP65/IP67 |
summary
| Installation Type | Wall surface installation |
| Net Weight | 337.74 g |
joggle
| Name | PROFIBUS DP |
| Attended Mode | 2x M12 connector, B encoding |
| Connection Point Identification | Copper cable |
| Propagation Velocity | 9,6 kBit / s... 12 MBit / s (Baud rate automatic detection) |
| Transmission Principle | PROFIBUS, D P is compatible with copper cable |
| Address Space Allocation | 1... 99, can be set |
| Digit Capacity | 5 |
Power supply for the electronic modules
| Attended Mode | M12 plug-in connector, (A encoding) |
| Name | UL |
| Supply Voltage | 24 V DC |
| Power Supply Voltage Range | 18 V DC... 30 V DC (including ripple) |
The Fieldline potential
| Voltage Source Ul | 24 V DC |
| Ul Source | 4 A |
| Ul Current Loss | Typical value of 40 mA |
| * Large for 100 mA | |
| Voltage Source Us | 24 V DC |
| Us Source | * Big 4 A |
| Us Current Loss | Typical value of 3 mA |
| * Large for 700 mA | |
| Voltage Power Supply, Ua11 | 24 V DC |
| The Ua11 Power Supply Unit | * Big 4 A |
| Current Loss At The Ua11 | Typical value of 12 mA (plus actuator current) |
| * Big 4 A | |
| Power Ua12 | 24 V DC |
| * Big 4 A | |
| Current Loss At The Ua12 | Typical value of 12 mA (plus actuator current) |
| * Big 4 A | |
| Voltage Power Supply, Ua21 | 24 V DC |
| Power Ua21 | * Big 4 A |
| Current Loss At The Ua21 | Typical value of 12 mA (plus actuator current) |
| * Big 4 A | |
| Voltage Power Supply, Ua22 | 24 V DC |
| Power Ua22 | * Big 4 A |
| Current Loss At The Ua22 | Typical value of 12 mA (plus actuator current) |
| * Big 4 A |
numeric output
| Ut Name | numeric output |
| Attended Mode | M12 Plug-in connector |
| Connected System | 2,3 Line |
| Number Of Output | 192:00:00 |
| Protect The Name | short-circuit protection |
| Output Voltage | 24 V DC |
| * Large Output Current For Each Channel | 2 A |
Electric isolation
| Pilot Section | The 24 V power supply (bus logic) / bus connection |
| 24 V power supply (bus logic) / FE 500 V AC 50 Hz 1 min. | |
| 24 V Power supply (bus logic) / Digital output (actuator supply) 500 V AC 50 Hz 1 min. | |
| Bus connection / FE 500 V AC 50 Hz 1 min. | |
| Bus Connection / Digital Output (Actuator Supply) 500 V AC 50 Hz 1 min. | |
| FE / Digital output (actuator supply) 500 V AC 50 Hz 1 min. |
Standards and Specifications
| Connection Meets The Criteria | CUL |
| Protection Level | III, IEC 61140, EN 61140, VDE 0140-1 |
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmental protection service
life: indefinite = EFUP-e
No
harmful substances exceeding the standard