ZZC
| Product features | |
| output signal | switching signal |
| measuring range | 0 10 bar0 145 psi |
| system interface | Thread connection G 1 / 4 outer thread inside thread: M5 |
| apply | |
| application | Used for industrial applications |
| medium | Liquid and gas media |
| Medium temperature [° C] | -25 80 |
| Minimum burst pressure | 300 bar4350 psi |
| compressive strength | 25 bar362 psi |
| pressure | relative pressure |
| Electrical data | |
| working voltage [V] | 9.6 32 DC |
| Current loss [mA] | < 25 |
| Insulation resistance minimum value [MΩ] | 100; (500 V DC) |
| levels of protection | III |
| phase-veversal protection | have |
| Total input / output | |
| Total number of inputs and outputs | Number of digital output: 1 |
| 输出 | |
| Output quantity | 1 |
| output signal | switching signal |
| electrical design | PNP |
| Number of digital outputs | 1 |
| output function | normally open |
| Switch volume output DC voltage drop maximum value [V] | 2 |
| Continuous current load of switch volume output DC [mA] | 500 |
| Switch frequency DC [Hz] | 100 |
| short-circuit protection | have |
| Short circuit protection type | impulse |
| overload protection | have |
| Measurement / setting range | |
| measuring range | 0 10 bar0 145 psi |
| switch point,SP | 0.5 10 bar7.5 145 psi |
| slow-moving | 0.2 bar2.9 psi |
| Precision / deviation | |
| Switch point precision [percentage of final value] | <± 2,5; (adjusting accuracy) |
| Repeat accuracy [percentage of final value] | <± 0,5; (Temperature fluctuation <10 K) |
| Characteristic curve deviation [percentage of final value] | <± 1,5 (BFSL) / <± 2,5 (LS); (BFSL = Best Fit Straight Line; LS = Limit Point Setting) |
| Rate of temperature change / 10 K | < ± 0.5 |
| Software / programming | |
| Switch point adjustment | circlip |
| going | |
| Environmental Temperature [°C] | -25 80 |
| Storage Temperature [°C] | -40 100 |
| Case protection grade | IP 67 |
| Certification / Test | |
| EMC electromagnetic compatibility | DIN EN 61000-6-2DIN EN 61000-6-3 |
| shock resistance | DIN IEC 68-2-2750 g (11 ms) |
| anti-seismic | DIN IEC 68-2-620 g (10 2000 Hz) |
| MTTF[year] | 576 |
| Component equipment instruction | Good engineering practice; can be used for group 2; fluid for group 1 as required |
| Mechanical technology data | |
| weight,[g] | 92.5 |
| raw and processed material | PBT; PC; FKM; Stainless steel (1.4404 / 316L) |
| Material (connecting parts) | Stainless steel (1.4404 / 316L); FKM |
| Switch action life | fifty million |
| Tightening the torque [Nm] | 25 |
| system interface | Thread connection G 1 / 4 outer thread inner thread: M5 |
| The Limiter element is integrated | No (fit) |
| Display / Operations | |
| show | Operation LED, green switch status LED, yellow |
| With scale | have |
| explanatory note | |
| packing unit | 1. A |
| Electrical connection | |
| joggle | Connector: 1 x M12 |